Steam table calculator
Enthalpy, entropy, volume and quality of water and steam from any two of temperature, pressure, enthalpy, entropy and dryness fraction, with saturation tables to download.
Known state
Superheated steam
IF97 region 2Saturation at 10 bar
boils at 179.89 °C| Property | Water (f) | Steam (g) |
|---|---|---|
| Specific enthalpy h, kJ/kg | 762.68 | 2777.1 |
| Specific entropy s, kJ/(kg·K) | 2.1384 | 6.585 |
| Specific volume v, m³/kg | 0.0011272 | 0.19435 |
Latent heat of vaporisation hfg = 2014.4 kJ/kg.
More properties
- Specific internal energy u
- 2793.7 kJ/kg
- Density ρ
- 3.8763 kg/m³
- Isobaric heat capacity cp
- 2.1408 kJ/(kg·K)
- Isochoric heat capacity cv
- 1.6081 kJ/(kg·K)
- Speed of sound w
- 578.51 m/s
- Equation used
- IF97 region 2Region 1 is compressed water, 2 steam, 3 the near-critical states, 4 the saturation line and 5 steam above 800 °C.
Saturation table
Free, no account, still being built: no guarantee that results are correct. Why free?
How the properties are calculated
Every number comes from IAPWS-IF97, the industrial formulation of the International Association for the Properties of Water and Steam that steam tables, boiler codes and process simulators use. It splits the states into five regions: compressed water (1), steam (2), the states near the critical point (3), the saturation line (4) and steam above 800 °C (5). Each region has its own equation; the page names the one it used.
Pressure with temperature, enthalpy, entropy or quality is solved with the release's own equations and its backward equations. Temperature with enthalpy or entropy, enthalpy with entropy and enthalpy or entropy with quality are solved by searching the pressure between the triple point and 100 MPa until the two given values meet. Where two states share both values, for example saturated steam of 2780 kJ/kg at 10.8 bar and at 64 bar, the page shows both.
Enthalpy, entropy and internal energy are zero for liquid water at the triple point, 0.01 °C and 611.657 Pa, as in every steam table.
Range
IAPWS-IF97 covers 0 °C to 800 °C up to 100 MPa and 800 °C to 2000 °C up to 50 MPa. Liquid and steam coexist from the triple point to the critical point at 373.946 °C and 220.64 bar; above both, water is a supercritical fluid. Values outside the range are refused or marked as extrapolated.
Sources
- IAPWS R7-97(2012), Revised Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam. Every verification table of the release is reproduced to better than 1 part in 107.
- W. Wagner and H.-J. Kretzschmar, International Steam Tables, 3rd ed., Springer 2019.