T-x-y and x-y diagrams
Bubble and dew curves of any two compounds at a fixed pressure or temperature, with the azeotrope marked beside the measured one, and the data to download.
Binary mixture
Ethanol and Water at 1 atm
UNIFAC (Dortmund)Measured azeotrope at 1 atm: 78.2 °C, x = 0.895 Ethanol (95.6 wt% Ethanol), Suzuki 1979.
Diagram data
| x Ethanol | y Ethanol | T, °C |
|---|---|---|
| 0.0000 | 0.0000 | 99.98 |
| 0.0250 | 0.2171 | 93.88 |
| 0.0500 | 0.3274 | 90.36 |
| 0.0750 | 0.3939 | 88.09 |
| 0.1000 | 0.4383 | 86.52 |
| 0.1250 | 0.4702 | 85.38 |
| 0.1500 | 0.4944 | 84.52 |
| 0.1750 | 0.5136 | 83.85 |
| 0.2000 | 0.5295 | 83.31 |
| 0.2250 | 0.5431 | 82.85 |
| 0.2500 | 0.5552 | 82.47 |
| 0.2750 | 0.5662 | 82.13 |
| 0.3000 | 0.5765 | 81.82 |
| 0.3250 | 0.5863 | 81.55 |
| 0.3500 | 0.5958 | 81.29 |
| 0.3750 | 0.6052 | 81.06 |
| 0.4000 | 0.6147 | 80.83 |
| 0.4250 | 0.6242 | 80.62 |
| 0.4500 | 0.6339 | 80.42 |
| 0.4750 | 0.6438 | 80.22 |
| 0.5000 | 0.6541 | 80.04 |
| 0.5250 | 0.6647 | 79.86 |
| 0.5500 | 0.6757 | 79.69 |
| 0.5750 | 0.6871 | 79.53 |
| 0.6000 | 0.6990 | 79.38 |
| 0.6250 | 0.7115 | 79.24 |
| 0.6500 | 0.7245 | 79.11 |
| 0.6750 | 0.7382 | 78.99 |
| 0.7000 | 0.7526 | 78.88 |
| 0.7250 | 0.7676 | 78.78 |
| 0.7500 | 0.7835 | 78.69 |
| 0.7750 | 0.8002 | 78.61 |
| 0.8000 | 0.8177 | 78.55 |
| 0.8250 | 0.8363 | 78.50 |
| 0.8500 | 0.8558 | 78.47 |
| 0.8750 | 0.8765 | 78.46 |
| 0.9000 | 0.8984 | 78.46 |
| 0.9250 | 0.9216 | 78.48 |
| 0.9500 | 0.9462 | 78.51 |
| 0.9750 | 0.9722 | 78.57 |
| 1.0000 | 1.0000 | 78.66 |
Component data
| Component | Tb, °C | Tc, °C | Pc, bar | ω |
|---|---|---|---|---|
| Ethanol64-17-5 · 46.07 g/mol · Tc from ChemSep | 78.7 | 240.8 | 61.48 | 0.649 |
| Water7732-18-5 · 18.02 g/mol · Tc from ChemSep | 100.0 | 374.0 | 220.6 | 0.344 |
Measured constants come from the ChemSep databank (Kooijman and Taylor, Artistic License 2.0). A compound it does not list is estimated from its structure by the group methods named, and every such value is marked. The components API gives each value with its source.
Free, no account, still being built: no guarantee that results are correct. Why free?
How the diagram is calculated
For 41 liquid compositions from pure second to pure first component the page solves the bubble point: the temperature (or, at fixed temperature, the pressure) at which the liquid starts to boil, and the composition y of the first vapour. The bubble curve plots T against x, the dew curve the same temperatures against y; between them liquid and vapour coexist. Where y equals x the mixture boils without changing composition: an azeotrope, found to 10−10 in x.
Each bubble-point liquid is then tested for a split into two liquid phases. Where it splits, as hexane and water or butanol and water do, the page finds the temperature at which both liquids boil together with one vapour and draws it as the flat three-phase line; if that vapour lies between the two liquids, it is a heterogeneous azeotrope.
Against the 26 azeotropes measured at 1 atm in the site's azeotrope table, UNIFAC (Dortmund) finds 25, on average 0.6 K and 0.015 in mole fraction from the measured point. Where the pair is in the table, the measured azeotrope is drawn beside the calculated one.
Which property package to choose
UNIFAC (Dortmund) predicts the activity coefficients from the functional groups and needs no fitted parameters, so it is the default. NRTL, UNIQUAC and Wilson are only as good as their binary parameters: none are stored here yet, so they are fitted to UNIFAC at the mean boiling point and say so under the diagram. Raoult's law suits similar molecules such as benzene and toluene; Peng-Robinson and SRK suit hydrocarbons and gases at high pressure but not water with alcohols.
Sources
- Activity models and flashes agree with Caleb Bell's thermo; the measured azeotropes come from Horsley-type tables (CRC Handbook, Dortmund Data Bank) as cited per row.
- U. Weidlich and J. Gmehling, Ind. Eng. Chem. Res. 26 (1987) 1372: modified UNIFAC (Dortmund).
- A. Fredenslund, R. L. Jones and J. M. Prausnitz, AIChE J. 21 (1975) 1086: UNIFAC.