Free, no account, still being built: no guarantee that results are correct. Why free?

Flash drum calculator

Split a feed into vapour and liquid at the drum temperature and pressure, a vapour fraction or the bubble and dew point: compositions, K-values and heat duty, and a second liquid when one forms.

Feed and drum

Components and mole fractions
Examples:

Hydrocarbons and gases: natural gas, refinery and petrochemical streams, also at high pressure.

Vapour and liquid

Peng-Robinson
Vapour fraction V/F0.3660
Temperature80.00°C
Pressure10bar
Vapour flow36.6kmol/h
Liquid flow63.4kmol/h
Heat to add402kWfrom feed to drum
ComponentFeed zVapour yLiquid xK = y/x
Propane0.30000.47250.20042.358
Butane0.30000.30230.29871.012
Pentane0.40000.22520.50090.4496
3 pairs have no fitted Peng-Robinson interaction parameter; kij = 0.

Propane–Butane, Propane–Pentane, Butane–Pentane

Phase properties and stream table

PropertyVapourLiquid
Flow, kg/h2000.33952.2
Molar mass, g/mol54.6562.34
Density, kg/m³22.44507.1
Molar enthalpy, kJ/mol−116.519−146.279
Heat capacity, J/(mol·K)115.2176.2
Viscosity, mPa·s9.75 × 10⁻³0.0993

Enthalpies are referred to the elements at 25 °C as ideal gases, so a heat duty between any two streams is their difference. The feed at 25.00 °C and 10 bar has −149.860 kJ/mol.

Component data

ComponentTb, °CTc, °CPc, barω
Propane74-98-6 · 44.10 g/mol · Tc from ChemSep−42.196.742.480.152
Butane106-97-8 · 58.12 g/mol · Tc from ChemSep−0.5152.037.960.199
Pentane109-66-0 · 72.15 g/mol · Tc from ChemSep36.1196.633.70.251

Measured constants come from the ChemSep databank (Kooijman and Taylor, Artistic License 2.0). A compound it does not list is estimated from its structure by the group methods named, and every such value is marked. The components API gives each value with its source.

Free, no account, still being built: no guarantee that results are correct. Why free?

How the flash is solved

An isothermal flash at the drum temperature and pressure first tests the feed for stability (Michelsen's tangent plane test), then splits it into vapour and liquid with the Rachford-Rice equation, Σ zi(Ki − 1)/(1 + V/F (Ki − 1)) = 0, and updates the K-values from the fugacities until they agree. Each liquid is tested again for a split into two liquids, and a third phase is kept only when it lowers the Gibbs energy, as water, a hydrocarbon and a gas do.

With a vapour fraction, or at the bubble or dew point, the temperature or the pressure is solved instead. The heat duty is the feed flow times the enthalpy difference between the drum and the feed at its own temperature and pressure; positive means heat is added.

Which property package to choose

Peng-Robinson or SRK for hydrocarbons, gases and refinery or natural gas streams, at any pressure. UNIFAC (Dortmund) or UNIFAC for polar liquids such as alcohols, water, ketones and esters at low pressure, where they predict the activity coefficients from the functional groups; NRTL, UNIQUAC and Wilson have no stored binary parameters yet and are fitted to UNIFAC, which the page says. Raoult's law for similar molecules such as benzene and toluene, as in textbook problems.

Sources
  • M. L. Michelsen, Fluid Phase Equilib. 9 (1982) 1 and 21: phase stability and the flash.
  • H. H. Rachford and J. D. Rice, J. Pet. Technol. 4 (1952) 19.
  • The flashes agree with Caleb Bell's thermo for 13 equation-of-state and 13 activity case sets within 6 × 10−5 K and 2 × 10−6 in mole fraction.

Report a problem